Comparing the economic and technical factors when using tied wire mesh and welded to make the reinforced concrete floor
1 year ago
Authors:
Nguyễn Thành Công,Từ Hồng Nhung
Publication date:
31 / 10 / 2021
Name of Publishers:
Industry and Trade Magazine
Abstract:
This paper is to analyze and design the reinforced concrete floor using tied wire mesh and welded wire mesh and compare the calculated results of the floor design of an actual building. Six typical floor cells with a total area of 114,93m2 are considered for economic, technical and construction time factors. As a result, welded wire mesh cuts costs more than 0,02 times, construction time is 0,01 times faster, steel quanlity is 0,1 times less. The design of welded wire mesh is simple, the construction technology is not complicated, the construction time depends on the supply capacity of the supplier. The influence of the above factors on the floor design using tied wire mesh and welded wire mesh is analyzed and clarified.